American Wheatley Pressure Vessels

At Industrial Air Services, we proudly supply American Wheatley, a trusted manufacturer of high-quality hydronic accessories and HVAC equipment. With decades of experience, American Wheatley is known for engineering durable, efficient solutions that support commercial, institutional, and industrial HVAC systems. Their products are designed to improve system performance, extend equipment life, and simplify maintenance.

Product Highlights

  • Hydronic Accessories – Including expansion tanks, air separators, and suction diffusers for system efficiency.

  • Heat Exchangers – Shell & tube and plate & frame designs for heating and cooling applications.

  • HVAC Specialties – Strainers, triple duty valves, and custom-fabricated components.

  • Custom Packaged Systems – Pre-engineered and skid-mounted HVAC solutions for turnkey installation.

  • Replacement Parts & Components – OEM-quality accessories to maintain performance and reliability.

Why Choose American Wheatley?

  • Proven expertise in hydronic and HVAC system support equipment

  • Wide product portfolio serving commercial and industrial facilities

  • Engineered for long-term reliability and system efficiency

Industrial Air Services
📞 (615) 641-3100
📍 138 Bain Drive • LaVergne, TN 37086

Contact Us

 
 

American Wheatley Hydronic Equipment FAQ

What does American Wheatley supply?

American Wheatley supplies hydronic and HVAC accessories, including expansion tanks, air separators, suction diffusers, strainers, and related equipment for heating and cooling systems.

What is a hydronic system?

A hydronic system uses water or another suitable liquid to carry heating or cooling energy. Pumps, piping, controls, and accessories work together to maintain circulation and operating conditions.

What does an expansion tank do?

An expansion tank accommodates liquid-volume changes as temperature varies. Correct sizing helps manage pressure within the intended range of a closed heating or cooling system.

How is an expansion tank sized?

Sizing considers system liquid volume, temperature range, fluid properties, fill pressure, and maximum allowable operating pressure. Nominal tank volume alone does not establish usable expansion capacity.

What is a diaphragm or bladder expansion tank?

A flexible membrane separates the system liquid from a gas cushion. Construction and serviceability vary, so confirm the selected tank's design and intended application.

Why is tank precharge important?

Precharge affects how the tank accepts expanding liquid. It must suit the system design and fill conditions and be checked using the manufacturer's specified procedure.

What does an air separator do?

An air separator helps remove entrained or dissolved air released within a circulating system. Its placement, temperature conditions, flow range, and vent arrangement affect performance.

Why is air removal useful?

Air can contribute to noise, unstable circulation, corrosion, and reduced heat transfer. Effective air management supports operation but should be combined with correct filling and system maintenance.

What is a suction diffuser?

A suction diffuser is a pump-inlet component that combines specified flow-conditioning and straining functions. Confirm the actual product features, pressure loss, and cleaning requirements.

What is a triple-duty valve?

A triple-duty valve combines designated check, balancing, and shutoff functions in one assembly. Suitability depends on the system's flow, pressure, and required operating characteristics.

Does American Wheatley offer heat exchangers?

American Wheatley's listed equipment includes heat exchangers for heating and cooling applications. Selection requires both fluid streams, flow rates, temperatures, pressure limits, and material requirements.

Can hydronic components be used with glycol?

Compatibility depends on the specific tank, seals, and other materials. Glycol concentration also changes fluid properties, which affects expansion calculations, pressure losses, and heat-transfer performance.

Can a heating expansion tank serve every water application?

No. The intended fluid service, temperature, pressure, and material requirements must match. Verify suitability for the exact application rather than assuming all water tanks are interchangeable.

What maintenance should be planned?

Inspect tanks, vents, strainers, valves, supports, and connected piping as applicable. Check pressure behavior and follow the product-specific instructions for membrane, precharge, or internal-component service.

Can existing hydronic equipment be replaced directly?

A replacement requires checking capacity, ratings, dimensions, connections, and current system conditions. System modifications may change the required tank size or accessory performance.

Where can I request American Wheatley equipment in Tennessee?

Contact Industrial Air Services at (615) 641-3100 with the application, system volume or flow, temperatures, pressures, and existing model information to discuss suitable hydronic components.