Adding a Bobcat compressor should solve a measured capacity, reliability, or expansion need—not just raise the pressure reading in the compressor room. Before selecting equipment, check how much air the plant actually uses, where pressure is being lost, and whether the existing controls, dryer, storage, and piping can handle another compressor.
For facilities evaluating Bobcat industrial air compressors in Knoxville, the question isn’t simply which machine fits the budget. It’s which machine fits the operating schedule and works properly alongside equipment already installed. That takes a look at the whole system before a purchase order is written.
Confirm Whether You Need More Air or Better Delivery
Low pressure at production equipment doesn’t automatically mean the plant needs another compressor. A restricted filter, undersized distribution line, failing regulator, or brief demand spike can create the same complaint.
Start by comparing pressure at the compressor discharge, downstream of air treatment, and near the equipment having trouble. Existing gauges and operating displays can help maintenance teams identify patterns. Temporary instrumentation and flow measurements should be handled by personnel qualified for that work.
Pressure falls throughout the system during sustained production: Available capacity may be insufficient, but compressor condition and leakage also deserve attention.
Header pressure stays steady while one department loses pressure: Investigate distribution restrictions and local demand before buying more capacity.
Pressure dips briefly when equipment cycles: Storage and the delivery path may matter more than another continuously running compressor.
Compressors run heavily during idle periods: Check compressed air leaks and equipment left consuming air.
A rotary screw compressor running continuously isn’t necessarily overloaded. Continuous operation can suit its assigned duty. The useful questions are whether it’s loaded, whether pressure holds, and how much capacity remains available.
Size the Addition Around Measured Demand and Planned Growth
Horsepower alone isn’t a reliable basis for choosing an additional compressor. Compare delivered airflow at the required operating pressure, using current manufacturer performance information. Confirm that quoted airflow figures use comparable rating conditions.
A compressed air system audit can establish demand across representative production shifts. Include startup, cleanup, low-production periods, and overlapping machine cycles—not just a quiet afternoon when someone happens to visit.
For planned expansion, gather each new machine’s pressure, air quality, and consumption requirements. Determine whether consumption figures describe average use or peak flow. Several machines with intermittent demand may create a substantial peak if their cycles overlap.
Leave room for documented growth, but don’t automatically buy the largest compressor the electrical service can support. Excess capacity can cause inefficient unloaded operation or control problems, depending on compressor design and demand patterns.
Decide What Job the Bobcat Compressor Will Do
The new unit needs a defined role. That decision affects equipment selection, control strategy, and whether the existing compressor remains useful.
Base-load or trim duty
A base-load compressor handles relatively steady demand. A trim compressor adjusts output as plant demand changes. If the proposed Bobcat compressor will handle trim duty, review its available capacity-control options and operating range against measured demand.
Variable-speed operation may suit changing loads, but it isn’t automatically the best choice. The usable speed range, minimum output, pressure requirements, and behavior of the other compressors all matter. Verify those details for the proposed model.
Standby or shared production duty
If the goal is backup capacity, define what must stay running during an outage. Keeping priority production equipment online is different from supporting the entire plant at full output.
An older compressor can remain useful as standby equipment, provided its condition supports that role. Review service history and test its operation. A machine that hasn’t run reliably for months shouldn’t be counted as dependable reserve capacity.
Work Out Controls Before Connecting the New Machine
Two compressors feeding the same header won’t necessarily share demand sensibly. Poorly coordinated pressure settings can leave both machines cycling, loading and unloading unnecessarily, or operating without a clear lead-and-trim relationship.
Before ordering, ask how the proposed Bobcat controls will coordinate with the existing equipment. Depending on the machines involved, the answer may involve coordinated pressure bands, lead/lag scheduling, or a compatible supervisory controller.
Don’t assume different controllers can communicate simply because both have remote connections. Confirm supported interfaces, permitted operating commands, and any additional hardware or programming required.
Control changes belong with trained compressed air technicians. Raising pressure or changing settings without reviewing the system can hide a restriction rather than correct it.
Check Everything Downstream of the Compressor
Another compressor increases available airflow. It doesn’t increase the capacity of the existing dryer, filters, receiver connections, or plant header.
Dryers, filters, and condensate removal
Determine whether the new compressor will have dedicated treatment or share the existing compressed air dryer and filtration. Shared equipment needs to accommodate the expected simultaneous flow under actual inlet temperature, ambient temperature, and pressure conditions.
This matters during Tennessee summers. A dryer that handled the original system may struggle with added airflow and hotter inlet air. Use the dryer manufacturer’s sizing corrections rather than relying only on its nominal flow rating.
Confirm the required air quality at production equipment, including pressure dew point—the temperature at which moisture begins condensing at operating pressure. Refrigerated drying may suit general indoor plant air, while colder piping or moisture-sensitive processes may need a different approach.
Check moisture separators, automatic drains, and condensate management capacity too. Adding airflow to a system with a clogged drain won’t solve water complaints.
Piping and receiver capacity
Review the connection point, header size, receiver arrangement, and pressure losses along the delivery path. A new compressor connected through a restrictive branch may not deliver its available capacity effectively.
Air receiver tanks can support short demand events and improve control stability. They don’t replace compressor capacity during a sustained shortage. Receiver sizing should reflect the demand event, allowable pressure change, and control strategy—not simply whatever tank fits the room.
A Knoxville Expansion Example
Consider a Knoxville machine shop planning another group of CNC machines. The existing compressor already spends much of the shift loaded, and operators report pressure dips at the far end of the shop.
That situation could justify additional capacity, but it could also involve a restrictive distribution branch. If pressure remains acceptable after the dryer while falling near the CNC equipment, adding a compressor alone may leave the complaint unresolved.
The useful approach is to measure demand, check pressure losses during overlapping machine cycles, and include the new equipment’s air quality requirements. The resulting plan might pair a Bobcat compressor with piping changes, added storage, or treatment upgrades. The measurements determine which work belongs in the proposal.
Review Installation and Service Access Before Accepting a Quote
The compressor’s footprint is only part of the space requirement. Leave manufacturer-specified room for cooling airflow, filter changes, cooler cleaning, and service access.
Have the proposed installation reviewed for:
Electrical supply capacity, starting requirements, protection, and connection work by qualified electrical personnel.
Ventilation capable of handling the combined heat from compressors operating together.
Approved isolation, check-valve arrangements, pressure relief, and accessible service points.
Suitable condensate collection and treatment.
A shutdown plan for the tie-in, including air compressor rentals if production can’t lose air.
Ask the supplier to identify what’s included and excluded. Equipment delivery, rigging, electrical work, piping, controls integration, startup, and operator instruction shouldn’t remain assumptions.
For Bobcat compressor solutions, verify current model specifications, service requirements, parts support, and warranty terms before committing. Commissioning should include checks under representative plant load, not just confirming that the motor starts.
Bottom Line
A suitable Bobcat addition needs to match plant demand and have a clear operating role. It also needs compatible controls and enough treatment, storage, piping, electrical capacity, and ventilation behind it.
Bring operating records, existing equipment details, and expansion plans to the consultation. Industrial Air Services can help evaluate whether another compressor is the right next step and which supporting changes belong in the installation.
Contact Industrial Air Services to discuss adding a Bobcat compressor to your Knoxville or East Tennessee facility’s existing air system.
Industrial Air Services is an authorized Bobcat® Industrial Air Compressors distributor serving Central to East Tennessee, including Nashville, Knoxville, and Chattanooga.
(615) 641-3100
138 Bain Drive • LaVergne, TN 37086